Features:
Eclipse
Simple. The Eclipse 3 is a single solution, better for your patients and your business.
Offers both continuous flow and pulse dosing options
One machine for stationary, ambulatory and travel needs
Lower operational costs by reducing monthly deliveries and simplifying inventory management
Maximum Medicare reimbursement with two billing codes: E1390 & E1392
Longer service intervals with lower maintenance costs
The only system on the market that can be upgraded in the field as new technology becomes available
Trusted. Patients want the freedom to enjoy life at a moment's notice and the peace of mind that the reliable Eclipse 3 delivers. It keeps up with the various activities of daily living while providing the individualized oxygen prescription. Oxygen anytime, anywhere.
Active and healthier patients create stronger referrals
Simplifies the patients' continuum of care with one device
No waiting for cylinder deliveries and replaces bulky equipment
The sleek design is small, quiet and can lower electric bills
AC/DC and battery power options extend therapy time and patient travel
FAA Approved for commercial airline travel
Accessory options that support an active lifestyle
Proven. The AARC suggests 'titrate to saturate' and the Eclipse was developed with that theory in mind. With a comprehensive dosing selection, a broader patient population can be treated at rest, during sleep, at exercise and at altitude. It's superior oxygen delivery.
autoSAT Technology, a pulse delivery system, maintains a consistent pulse dose volume for every breath as your patients respiratory rate changes
Consistently delivers a fixed pulse dose volume up to 96mL (in increments of 16mL) in addition, three new pulse dose volumes of 128mL, 160mL and 192mL
New control panel displays in either LPM or mL for more accurate prescription verification
Can be used with CPAP and bi-level devices in Continuous Flow
autoSAT Technology
Approved for Rx of 0.5 - 3.0 LPM continuous flow
Pulse Dose volumes up to 96mL (in increments of 16mL) in addition three new pulse dose volumes of 128mL, 160mL and 192mL
mL and LPM dose LCD Display
Three available rise time options-Fast, Medium and Slow
Adjustable Pulse Dose sensitivity settings
New innovative Universal Cart design allows for easy access to battery
New AC and DC adapters that are smaller in size yet more durable
More user-friendly alarm package
In Pulse Dose Mode, if an inspiratory effort is not detected, the device will deliver a continuous flow of oxygen; continually searching for a breath every 15 seconds.
Easy-access service and maintenance information
Dimensions:
Eclipse: 12.3 in. (31.2 cm) x 19.3 in. (49 cm) x 7.1 in. (18 cm)
Integra: 14.7 in. (37 cm) x 19.5 in. (50 cm) x 26.5 in. (66 cm)
Weight:
Eclipse: 15 lbs. (6.8 kg), 18.4 lbs. (8.35 kg) with battery, Intergra: 57 lbs. (26 kg)
Warranty:
Available with various warranties
Alert / Alarm:
Eclipse: Loss of power, Low Power Cartridge, Low Therapeutic Oxygen Output, Oxygen flow outside normal limits, No inspiration detected in, Pulse Dose Mode, Unit Malfunction
Integra: Power Interruption, Power Surge (simulated circuit b
Back Up Alarm Power:
9V Battery
FAA Aproved:
Yes
Battery Charging:
Integra: 1.8 to 5.0 hrs, dependent upon the flow recharge time setting, to achieve 80% capacity from a fully discharged Power Cartridge
Battery Duration:
Eclipse: 2.0 hours at 2.0 LPM Continuous Flow
1.3 hours at 3.0 LPM Continuous Flow
5.2 hours at 2.0 Pulse Dose setting,12bpm
3.5 hours at 6.0 Pulse Dose setting,12bpm
Electrical:
Intergra: 115V ~, 60 Hz, 5.0A Nominal220-240V ~, 50Hz, 2.2A Nominal
Flow Control Settings:
Eclipse: Continuous Flow: .5 to 3.0 LPM (0.5 liter increments)
Pulse Dose: 16 - 96 (16 mL increments), 128mL, 160 mL, 192 mL
Flow Rate:
Integra: 0.5 - 10 LPM
Indicator:
Integra: Green Light = Normal OperationYellow Light Flashing = Below Normal Operation (85%)Red Light Flashing = Abnormal
Noise Level:
Integra: 48 Decibels at 3.0 LPM Continuous Flow Mode40 Decibels at 3.0 Pulse Dose setting
Operating ranges, Intended for Use:
Eclipse: Temperature: 50 to 104 F (10 to 40 C) at 82.4 F (28 C) dew point, non-condensing
Altitude: 0 to 13,123 ft. (0 to 4000 meters)
Integra: Temperature: 50 F to 104 F (10 C to 40 C)
Humidity: Up to 95% Non-Condensing
Outlet Pressure:
Eclipse: 5.0 psi (34.5 kPa) nominal
Integra: Nominal 6.0 PSI (41.4 kPa)Maximum 11.0 PSI (75.8 kPa)
Oxygen Concentration:
Eclipse: 90% (+/- 3%) @ sea level
Integra: 91% (+/- 3%) on 1.0 to 10.0 LPM at sea level
Power:
Eclipse: AC Operation: 100-240 VAC, 50-60 Hz
DC Input: 13.5-15 VDC, 10A
Power Cartridge: Quantity (2) 97.5 W-Hr battery packs each containing
7.92 grams of equivalent lithium content
Power Consumption:
Eclipse: 52 watts at 1.0 LPM continuous flow
145 watts at 3.0 LPM continuous flow
45 watts at 1.0 pulse dose setting
95 watts at 6.0 pulse dose setting
Storage Ranges, Intended for Storage:
Temperature: -4 F to 140 F (-20 C to 60 C)
Humidity: Up to 95% Non-Condensing
Transportation:
Keep dry, handle with care.
Trigger Sensitivity:
Eclipse: Adjustable between -0.125 cm H2O to -0.40 cm H2O