Features:
The Eclipse 3 is a single solution, offering both continuous flow and pulse dosing options
One machine for stationary, ambulatory and travel needs
AC/DC and battery power options extend therapy time and patient travel
FAA Approved for commercial airline travel
Accessory options that support an active lifestyle
autoSAT Technology
Approved for Rx of 0.5 - 3.0 LPM continuous flow
Pulse Dose volumes up to 96mL (in increments of 16mL) in addition three new pulse dose volumes of 128mL, 160mL and 192mL
mL and LPM dose LCD Display
Three available rise time options-Fast, Medium and Slow
Adjustable Pulse Dose sensitivity settings
New innovative Universal Cart design allows for easy access to battery
New AC and DC adapters that are smaller in size yet more durable
In Pulse Dose Mode, if an inspiratory effort is not detected, the device will deliver a continuous flow of oxygen; continually searching for a breath every 15 seconds.
Easy-access service and maintenance information
Dimensions:
12.3 in. (31.2 cm) x 19.3 in. (49 cm) x 7.1 in. (18 cm)
Weight:
15 lbs. (6.8 kg), 18.4 lbs. (8.35 kg) with battery
Warranty:
3 Year Manufacturers Warranty on Unit
1 Year Warranty on Accessories
Alert / Alarm:
Loss of power, Low Power Cartridge, Low Therapeutic Oxygen Output, Oxygen flow outside normal limits, No inspiration detected in, Pulse Dose Mode, Unit Malfunction
Back Up Alarm Power:
9 Volt Battery
FAA Aproved:
Yes
Battery Charging:
1.8 to 5.0 hrs, dependent upon the flow recharge time setting, to achieve 80% capacity from a fully discharged Power Cartridge
Battery Duration:
Up to 3.7 hours at 1.0 LPM continuous flow
Up to 1.3 hours at 3.0 LPM continuous flow
Up to 4.4 hours at 1.0 pulse flow setting
Up to 2.1 hours at 6.0 pulse flow setting
Flow Control Settings:
Continuous Flow: .5 to 3.0 LPM (0.5 liter increments)
Pulse Dose: 16 - 96 (16 mL increments), 128mL, 160 mL, 192 mL
Noise Level:
48 Decibels at 3.0 LPM Continuous Flow Mode, 40 Decibels at 3.0 Pulse Dose setting
Operating ranges, Intended for Use:
Temperature: 50 to 104 F (10 to 40 C) at 82.4 F (28 C) dew point, non-condensing
Altitude: 0 to 13,123 ft. (0 to 4000 meters)
Outlet Pressure:
5.0 psi (34.5 kPa) nominal
Oxygen Concentration:
90% (+/- 3%) @ sea level
Power:
AC Operation: 100-240 VAC, 50-60 Hz
DC Input: 13.5-15 VDC, 10A
Power Cartridge: Quantity (2) 97.5 W-Hr battery packs each containing
7.92 grams of equivalent lithium content
Power Consumption:
52 watts at 1.0 LPM continuous flow
145 watts at 3.0 LPM continuous flow
45 watts at 1.0 pulse dose setting
95 watts at 6.0 pulse dose setting
Transportation:
Keep dry, handle with care.
Trigger Sensitivity:
Adjustable between -0.125 cm H2O to -0.40 cm H2O